 Features

4:1 Wide Input Voltage Range 10 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 84%
POWERLINE
DC/DC-Converter
RP10S_DEW Series
10 Watt 2" x 1" Package Single & Dual Output
Selection Guide 24V and 48V Input Types
Part Number Input Range VDC 9-36 9-36 9-36 18-75 18-75 18-75 9-36 9-36 9-36 18-75 18-75 18-75 Output Voltage VDC 5 12 15 5 12 15 5 12 15 5 12 15 Output Current mA 2000 830 670 2000 830 670 1000 416 333 1000 416 333 Input (4) Current mA 548 532 551 274 259 262 548 547 548 271 281 270 Efficiency(5) Capacitive(6) Load max. % F 80 82 80 80 84 84 80 80 80 81 78 81 4700 690 470 4700 690 470 680 330 110 680 330 110
RP10-2405SEW RP10-2412SEW RP10-2415SEW RP10-4805SEW RP10-4812SEW RP10-4815SEW RP10-2405DEW RP10-2412DEW RP10-2415DEW RP10-4805DEW RP10-4812DEW RP10-4815DEW
* add suffix /M2 for higher efficiencies and extended temperature range. M P * add /P for CTRL function with Positive Logic (1=ON, 0=OFF) N * add /N for CTRL function with Negative Logic (0=ON, 1=OFF)
224
July-2006
www.recom-international.com
POWERLINE
DC/DC-Converter
RP10-S_DEW Series
RP10-2405SEW With Heat Sink
125 100
Derating-Graph (Ambient Temperature)
RP10-2405SEW
125 100 75 Output Power (%) 50 25 0 -25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
75 50 25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (C) 75 0 -25
Natural Convection
Ambient Temperature Range (C)
RP10-2405DEW
125 100 75 Output Power (%) Output Power (%) 50 25 0 -25
125 100 75
RP10-2405DEW With Heat Sink
Natural Convection
50 25 0 -25
Natural Convection
50 60 70 80 90 100 Ambient Temperature Range (C) 74
-10 0
-10 0
50 60 70
Ambient Temperature Range (C)
80 90 100 78
125 100 75 Output Power (%) 50 25
RP10-2405SEW/M2
125 100 75 Output Power (%)
RP10-2405SEW/M2 With Heat Sink
Natural Convection
50 25
Natural Convection
50 60 70 Ambient Temperature Range (C)
0 -40 -25 -10 0
80 90 100
50 60 70 80 90 100 Ambient Temperature Range (C) 75
0 -40 -25 -10 0
125 100 75 Output Power (%) 50 25
RP10-2405DEW/M2
125 100
RP10-2405DEW/M2 With Heat Sink
Output Power (%)
Natural Convection
75 50 25
Natural Convection
50 60 70 80 90 100 Ambient Temperature Range (C) 74
0 -40 -25 -10 0
0 -40 -25 -10 0
50 60 70
Ambient Temperature Range (C)
80 90 100 78
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at
www.recom-international.com July-2006 225
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25C unless otherwise noted)
Input Voltage Range Input Filter Input Surge Voltage (100 ms max.) Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (Optional. See Note 7) (Positive logic) (Negative logic) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin) Minimum Load (see Note 1) Line Regulation (low line, high line at full load) Load Regulation (25% to 100% full load) Cross Regulation (asymmetrical load 25%/100% full load) Ripple and Noise (20MHz bandwith) Single Dual Temperature Coefficient Transient Response (25% load step change) Over Voltage Protection Zener diode clamp Over Load Protection (% of full load at nominal Vin) Short Circuit Protection Efficiency Isolation Voltage Isolation Resistance Isolation Capacitance Operating Frequency Operating Temperature Range (Reference Derating Curve) (see Note 9) Maximum Case Temperature Storage Temperature Range Thermal Impedance (see Note 8) Thermal Shock Standard M2 5V output 12V output 15V output Single Dual DC-DC ON DC-DC OFF DC-DC ON DC-DC OFF Nominal input 24V Input 48V Input
RP10-S_DEW Series
24V nominal input 48V nominal input 9-36VDC 18-75VDC Pi Type 50VDC 100VDC 30mAp-p 20ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V Short or 0V < Vr < 1.2V Open or 3.5V < Vr < 12V 20mA 10W max. 2% 10% of full load 1% 1% 2% 5% 50mVp-p 75mVp-p 0.02%/C max. 500s 6.2V 15V 18V 150% typ Hiccup, automatic recovery see Selection Guide" table 1600VDC min. 1 G min. 300pF max. 300kHz typ. -25C to +85C(with derating) -40C to +85C(with derating) +100C -55C to +105C Natural convection Natural convection with Heat Sink 12C/Watt 10C/Watt MIL-STD-810D continued on next page
226
July-2006
www.recom-international.com
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25C unless otherwise noted)
Vibration Relative Humidity Case Material Base Material Potting Material Conducted Emissions (see Note 10) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Weight Dimensions MTBF (see Note 2) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6
RP10-S_DEW Series
10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Nickel plated copper Non-conductive black plastic Epoxy (UL94-V0) Level A Level A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 27g 50.8 x 25.4 x 10.2mm 1976 x 103 hours
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listedspecification. 2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40C. (Ground fixed and controlled environment). 3. Simulated source impedance of 12H. 12H inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P) Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N). If no suffix is specified, the control pin will be omitted. 8. Heat sink is optional and P/N: 7G-0020A. 9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version. 10. See application notes for EMI-filtering.
www.recom-international.com
July-2006
227
POWERLINE
DC/DC-Converter
Package Style and Pinning (mm)
RP10-S_DEW Series
3rd angle projection
50.80
25.40 10.20
dia. 1.0 15.20 20.30
5.6 2.50 5.10
Pin Connections
3 1 2 6
Bottom View
10.20
4
10.20
5
12.70
Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* * Optional. See Note 7
Dual +Vin -Vin +Vout Com -Vout CTRL*
Pin Pitch Tolerance 0.35 mm
228
July-2006
www.recom-international.com


▲Up To Search▲   

 
Price & Availability of RP10-4815SEWP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X